Laboratorio de calibración especializado en
Miami, Florida

Horarios de apertura

Lun
08:00 - 04:00
Mar
08:00 - 04:00
Mier
08:00 - 04:00
Juv
08:00 - 04:00
Vie
08:00 - 04:00
Contacto
(561) 999-1896
554 NW 77th Street
Boca Raton, FL 33487

ACREDITACIONES

ISO/IEC 17025

ANSI/NCSL Z540-1

ANSI/NCSL Z540.3

Scope of accreditation
A2LA Cert #1877.02

A2LA Cert #1877.02

ISO/IEC 17025

ISO/IEC 17025

ANSI/NCSL Z540-1-1994

ANSI/NCSL Z540-1-1994

ANSI/NCSL Z540.3-2006

ANSI/NCSL Z540.3-2006

CAPACIDADES

Capacidades acreditadas
Capacidades trazables
Liquid flow
Gas flow
Fuerza
Química
Dimensional
Electricidad
Liquid flow
Humedad
Mass / Scale
Pressure / Vacuum
Temperatura
Par
Volumen
Liquid flow

Liquid flow

Capacidades acreditadas

Global Calibration Scope: Liquid flow (water): 0.12 l/h to 120 m3/h; Liquid flow (Hydrocarbon oils (Kerosene, Gas oil, Shell Tellus 32, Shell Tellus 100)): 0.6 l/min to 3000 l/min

Common equipment serviced: Liquid flow meter, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Gas flow

Gas flow

Capacidades acreditadas

Global Calibration Scope: Gas flow (air): 0.5 ml/min to 4000 m3/h (the range is lower depending on gas used (nitrogen, argon or any inert gases)

Common equipment serviced: Anemometers (thermal & vane), Bubble flowmeters, Gas flow meters, Gas meters, Thermal mass flow controllers, Variable area flow meters, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Fuerza

Fuerza

Capacidades acreditadas

Global Calibration Scope

  • Push pull force measuring devices in tension and compression: up to 1 MN
  • Force machine: up to 5 MN (compression) and up to 1 MN (tension)

Common equipment serviced: Dynamometers, Force machines (Tension and/or Compression), Load cell, Force gauges, Strainmeter, Crimping pliers, Charpy testers, Cable tie tools, Press, Retention tools, Wire wrap tools, Spring balance

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Química

Química

Capacidades acreditadas

Calibration Scope

  • ≈ 4pH, ≈ 7pH, ≈ 10pH
  • ≈10 µS/cm,≈ 00 µS/cm,≈1000 µS/cm,≈10000 µS/cm
  • ≈various gasses
  • ≈verified against standard hydrometer set using various liquids
  • ≈verified using various standard fluids
  • ≈1000 cP to 60000 cP
  • ≈up to 6000 ft/min
  • ≈up to 99000 RPM

Common equipment serviced: pH – Measuring Equipment, Electrolytic Conductivity – Measuring Equipment, Gas Analyzers, Hydrometers, Refractometers, Viscometers, Laminar Flow Hoods, Centrifuges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Dimensional

Capacidades acreditadas

Calibration Scope

  • ≈Traceable for protractors
  • ≈16 µin + 5.5 µin/in
  • ≈74 µin
  • ≈19 µin + 5.6 µin/in
  • ≈31 µin + 5.2 µin/i

Common equipment serviced: Angle Measuring, Micrometers, Length Indicators, Height Gages, Calipers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricidad

Electricidad

Capacidades acreditadas

Calibration Scope

STANDARD ELECTRICITY:

  • Voltage generation up to 1 kV DC and 1 kV AC; voltage measurement up to 1  kV DC and 40 kV AC
  • Electrical temperature simulation: RTD, TC
  • Current up to 1000 A DC and 200 A AC
  • Resistance generation up to 1100 MΩ, measure up to 20 GΩ
  • Phase 0 to 360 ° @ 10 to 30 KHz
  • Capacitance generate 0.19 nF to 110 mF
  • Oscilloscopes up to 1100 MHz
  • Optical tachometers

Common equipment serviced: Digital Multimeters, Oscilloscope, Power supplies, Megohmmeter, Insulation Testers, Function Generator, Power Quality, Ohmmeters, Clamp Meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Liquid flow

Liquid flow

Capacidades acreditadas

Calibration Scope

  • 0.7 to 180 GPM

Common equipment serviced: Liquid Flow Meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humedad

Humedad

Capacidades acreditadas

Calibration Scope

  • Humidity Generate 10 to 80 % RH using Chamber, measure 10 to 100 % using hygrometer

Common equipment serviced: Hygrometers, Probes, Psychrometers, etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Mass / Scale

Capacidades acreditadas

Calibration Scope

  • All classes of weights 1 mg to 20 Kg – Comparison, 1 mg to 32 Kg direct weigh
  • Up to 32 Kg
  • Up to 3000 lb Class F weights, up to 6000 lbs with substitution

Common equipment serviced: Standardized and non-standard weights, Balances, Scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Capacidades acreditadas

Calibration Scope

  • Absolute – relative – differential pressure : gas up to 10,ooo PSI / water & oil up to 36000 PSI

Common equipment serviced: Calibrators, Digital pressure gauges, Sensors/Transmitters, Needle pressure gauges, etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperatura

Temperatura

Capacidades acreditadas

Calibration Scope

  • Generate -40 °C to 300 °C with immersion baths, ovens using PRTs to monitor
  • -10 °C to 400 °C with dry well
  • 600 °C to 1200 °C with dry well furnace monitored by TC
  • Measure -197 °C to 660 °C using PRT
  • -15 °C to 500 °C

Common equipment serviced: Temperature thermometers and probes, Calibrators, Pyrometers, Enclosures, Furnaces and Ovens…, IR Thermometer

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Par

Par

Capacidades acreditadas

Calibration Scope

  • From 5 lbf-in  to 600 lbf-ft

Common equipment serviced:Torque sensors, Torque meters, Torque tools

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Volumen

Volumen

Capacidades acreditadas

Calibration Scope

  • From 1 µl to 10 ml

Common equipment serviced: Pipettes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Liquid flow
Gas flow
Fuerza
Química

Calibration Scope

  • ≈ 4pH, ≈ 7pH, ≈ 10pH
  • ≈10 µS/cm,≈ 00 µS/cm,≈1000 µS/cm,≈10000 µS/cm
  • ≈various gasses
  • ≈verified against standard hydrometer set using various liquids
  • ≈verified using various standard fluids
  • ≈1000 cP to 60000 cP
  • ≈up to 6000 ft/min
  • ≈up to 99000 RPM

Common equipment serviced: pH – Measuring Equipment, Electrolytic Conductivity – Measuring Equipment, Gas Analyzers, Hydrometers, Refractometers, Viscometers, Laminar Flow Hoods, Centrifuges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Calibration Scope

  • ≈Traceable for protractors
  • ≈16 µin + 5.5 µin/in
  • ≈74 µin
  • ≈19 µin + 5.6 µin/in
  • ≈31 µin + 5.2 µin/i

Common equipment serviced: Angle Measuring, Micrometers, Length Indicators, Height Gages, Calipers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricidad

Calibration Scope

STANDARD ELECTRICITY:

  • Voltage generation up to 1 kV DC and 1 kV AC; voltage measurement up to 1  kV DC and 40 kV AC
  • Electrical temperature simulation: RTD, TC
  • Current up to 1000 A DC and 200 A AC
  • Resistance generation up to 1100 MΩ, measure up to 20 GΩ
  • Phase 0 to 360 ° @ 10 to 30 KHz
  • Capacitance generate 0.19 nF to 110 mF
  • Oscilloscopes up to 1100 MHz
  • Optical tachometers

Common equipment serviced: Digital Multimeters, Oscilloscope, Power supplies, Megohmmeter, Insulation Testers, Function Generator, Power Quality, Ohmmeters, Clamp Meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Liquid flow

Calibration Scope

  • 0.7 to 180 GPM

Common equipment serviced: Liquid Flow Meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humedad

Calibration Scope

  • Humidity Generate 10 to 80 % RH using Chamber, measure 10 to 100 % using hygrometer

Common equipment serviced: Hygrometers, Probes, Psychrometers, etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Masa / Escala

Calibration Scope

  • All classes of weights 1 mg to 20 Kg – Comparison, 1 mg to 32 Kg direct weigh
  • Up to 32 Kg
  • Up to 3000 lb Class F weights, up to 6000 lbs with substitution

Common equipment serviced: Standardized and non-standard weights, Balances, Scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Presión / Vacío

Calibration Scope

  • Absolute – relative – differential pressure : gas up to 10,ooo PSI / water & oil up to 36000 PSI

Common equipment serviced: Calibrators, Digital pressure gauges, Sensors/Transmitters, Needle pressure gauges, etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperatura

Calibration Scope

  • Generate -40 °C to 300 °C with immersion baths, ovens using PRTs to monitor
  • -10 °C to 400 °C with dry well
  • 600 °C to 1200 °C with dry well furnace monitored by TC
  • Measure -197 °C to 660 °C using PRT
  • -15 °C to 500 °C

Common equipment serviced: Temperature thermometers and probes, Calibrators, Pyrometers, Enclosures, Furnaces and Ovens…, IR Thermometer

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Par

Calibration Scope

  • From 5 lbf-in  to 600 lbf-ft

Common equipment serviced:Torque sensors, Torque meters, Torque tools

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Volumen

Calibration Scope

  • From 1 µl to 10 ml

Common equipment serviced: Pipettes

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Secret Link