Laboratorio de calibración especializado en
Tananger – Norway

Horarios de apertura

Lun
07:30 - 15:30
Mar
07:30 - 15:30
Mier
07:30 - 15:30
Juv
07:30 - 15:30
Vie
07:30 - 15:30
Contacto
+47 51 71 95 00
NorSea Base, Bygg 53
4056 Tananger
Norway

CAPACIDADES

Capacidades acreditadas
Capacidades trazables
Dimensional
Electricidad
Humedad
Fuerza
Temperatura
Mass / Scale
Par
Pressure / Vacuum
Thermal and climatic testing
Dimensional

Dimensional

Capacidades acreditadas

Global Calibration Scope

  • Gauge block (steel, tungsten carbide, ceramic…): up to 1500 mm
  • Long length (standard tape rules, peripheral gauges…): up to 100 m

Common equipment serviced: Angle instruments, Measuring bench/optical, Depth gauge, Gauge blocks, Height gauges, Micrometers, Length instruments, Limit gauges, Form and surface, Thread gauges

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricidad

Electricidad

Capacidades acreditadas

Global Calibration Scope

  • AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
  • High voltage:
    • DC: 1 kV to 200 kV
    • AC (50 Hz): 1 kV to 175 kV
  • Magnetometers: 0 to 1700 mT…

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humedad

Humedad

Capacidades no acreditadas

Our laboratory calibrates humidity sensors between 10-90 % RH at 20±2°C

Fuerza

Fuerza

Capacidades no acreditadas

Compression: up to 1 MN

Tension: up to 125 kN

Temperatura

Temperatura

Capacidades acreditadas

Our laboratory in Tananger calibrates most temperature measurement systems. Our range is -196 to 660°C.

ITS-90 fixed point references

  • Ice: 0.01 ° C Triple point for water
  • Gallium: 29.7646 ° C
  • Zinc: 419.527 ° C
  • Aluminum: 660,323 ° C
Mass / Scale

Mass / Scale

Capacidades acreditadas
  • Accredited calibration of masses (weights/load) at our laboratory in Tananger
    • Measuring range: 100 mg – 20 kg
    • CMC from 0.26 mg
  • Accredited calibration of scales/balances by customer
    • Measuring range: 100 mg – 60 kg
    • CMC from 0.16 mg
  • Traceable calibration of scales/balances up to 2000 kg
  • Traceable calibration of masses (weights) up to 60 kg
Par

Par

Capacidades no acreditadas

Our Laboratory in Tananger calibrates torque wrenches from 0 – 1500 Nm

Pressure / Vacuum

Pressure / Vacuum

Capacidades acreditadas
  • We cover the pressure range from absolute vacuum to 5000 bar.
  • Traceability to LNE, DHI, RISE and Justervesenet
  • Our best uncertainty is 30 ppm
  • We calibrate differential pressure with up to 400 bar line pressure and 5 bar differential pressure.
Thermal and climatic testing

Thermal and climatic testing

Capacidades acreditadas

Global Scope

  • 3 to 98 %RH
  • -100 to 1250°C

Common equipment serviced: Climatic chamber, Thermostatic chamber, Refrigerator, Freezer, Oven, etc.

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional
Electricidad
Humedad

Our laboratory calibrates humidity sensors between 10-90 % RH at 20±2°C

Fuerza

Compression: up to 1 MN

Tension: up to 125 kN

Temperatura

Our laboratory in Tananger calibrates most temperature measurement systems. Our range is -196 to 660°C.

ITS-90 fixed point references

  • Ice: 0.01 ° C Triple point for water
  • Gallium: 29.7646 ° C
  • Zinc: 419.527 ° C
  • Aluminum: 660,323 ° C
Masa / Escala
  • Accredited calibration of masses (weights/load) at our laboratory in Tananger
    • Measuring range: 100 mg – 20 kg
    • CMC from 0.26 mg
  • Accredited calibration of scales/balances by customer
    • Measuring range: 100 mg – 60 kg
    • CMC from 0.16 mg
  • Traceable calibration of scales/balances up to 2000 kg
  • Traceable calibration of masses (weights) up to 60 kg
Par

Our Laboratory in Tananger calibrates torque wrenches from 0 – 1500 Nm

Presión / Vacío
  • We cover the pressure range from absolute vacuum to 5000 bar.
  • Traceability to LNE, DHI, RISE and Justervesenet
  • Our best uncertainty is 30 ppm
  • We calibrate differential pressure with up to 400 bar line pressure and 5 bar differential pressure.
Ensayos térmicos y climáticos
Secret Link